Fire Protection logo                   

FIRE  PROTECTION  OF  CANADA  INC.

Regina, SK

Ph: (306)721-6490               Fax: (306)789-3450


 Kidde® Fire Systems

 

Clean Agent Systems

FM-200 (Heptafluoropropane, CF3-CHF-CF3) Kidde-Fenwal Systems

Clean, fast active fire protection for sensitive industrial and commercial facilities.

FM-200 EXTINGUISHES A FIRE IN 10 SECONDS OR LESS

Fires grow at exponential rates until fully involved. Heat and smoke damage for delicate electronics is greatest in the first few minutes, and the generation of deadly combustion products is often greater in the initial stages of a fire. FM-200 will completely knock down Class A, B and C fires in 10 seconds or less - before the fire can effectively develop. Stopping the fire in those critical few seconds can save millions of dollars worth of equipment and lost production. Other extinguishants can take 60 seconds or longer to react. And that delay can translate to serious damage and substantial repair and downtime. FM-200's fast action and excellent explosion inerting capabilities can prevent catastrophic consequences.

WHY IT WORKS SO WELL

FM-200's mechanism of extinguishing fires is active. Its primary action is through physically cooling the fire at the molecular level. FM-200 (HFC-227ea) belongs to the same class of compounds used in refrigeration, and, as such, is an efficient heat transfer agent. FM-200 literally removes heat energy from the fire to the extent that the combustion reaction cannot sustain itself. Additionally, there is a chemical extinguishing action contributed by FM-200. Trace amounts of free radicals are released in a fire, ultimately inhibiting the chain reaction of combustion.

 

ADVANTAGES

 FAST ACTION Kidde-Fenwal FM-200 Systems are designed to fully discharge within 10 seconds after receiving an actuation signal. Less time for a fire to grow or cause damage.
 CLEAN FM-200 discharges as a gas, reaching into all areas of the protected facility but leaving no residue to damage sensitive equipment or require costly cleanup. Enables companies to be back to business faster after a fire.
 ENVIRONMENTALLY FRIENDLY FM-200 has an ozone depletion potential of zero. FM-200 also has very low global warming properties and atmospheric lifetime (31-42 years). It is an active agent listed in the EPA's Significant New Alternatives Policy (SNAP) with no use restrictions. Enables system owners to comply with current and future environmental regulations.
 ECONOMICAL DESIGN Kidde® FM-200 Systems use an engineered central storage design that enables one system to protect multiple hazards. More cost-effective fire protection.
 PROVEN TECHNOLOGY Kidde® FM-200 Systems represent advancements in fire protection based on technologies that are solving user problems world wide. The Kidde name means superior clean agent fire suppression.
 INTEGRATED SYSTEMS As a Kidde® distributor, we can design, install and maintain a completely integrated system of fire detection, control and clean agent suppression to meet virtually any fire protection challenge. Rely on FireCANADA® for the total system solution.

For more information go to http://www.e1.greatlakes.com/fm200/jsp/index.jsp

TYPICAL APPLICATIONS

 Computer Room

  •  Chemical Storage Areas
  • Libraries
  •  Cleanrooms
  • Manufacturing Processes
  •  Communications Facilities
  • Museums
  •  Computer Areas
  • Process Control Centers
  •  Data Processing Libraries
  • Records Storage Rooms
  •  Emergency Power Facilities
  • Robotics
  •  Laboratories
  • Telephone Equipment Rooms

 

DESIGN CRITERIA

Kidde-Fenwal FM-200 Systems are recommended where one or more of the following conditions are involved:

  • Either the value of the area's contents or the area's importance to business continuity requires a fire suppression system that can react in seconds.
  • Water sprinklers are not available, or if present, may damage the contents of the area to be protected.
  • Personnel occupy the area to be protected.
  • There is a need for a fire suppression system that employs an agent requiring no post fire cleanup.
  • There is a limited amount of storage space for the extinguishing agent containers.

 

  • WHAT FM-200 DOES NOT DO

    • Leave residue

    • Cause cold shock

    • Interrupt electrical circuits

    • Reduce oxygen

    • Cause toxicity

    • Deplete the ozone

    • Contribute to global warming

    Great Lakes Chemical Corp. manufactures FM-200 under the strict international quality standards of ISO 9002

       

** Detection is easy with a Scorpio® Fire/Suppression control panel**

 

  Order all system components from FIRE PROTECTION OF CANADA INC.

Fire Protection logo

  Back to home Page